Yoga - What is Yoga?Yoga Course Offerings - Yoga Courses at SVYASAYoga Training & Research DivisionsArogyadhama - Yoga Research Health HomeA leading Yoga Research InstitutionYoga LibraryEvents @ SVYASAAbout SVYASA and VYASA
 
Yoga » Yoga University » Yoga Library » Yoga Research Papers » Yoga and Life Sciences
Yoga Research Papers published by SVYASA


RESULTS 

[1] Comparison of peak latencies between congenitally blind subjects and those with normal vision showed a significant difference (two factor ANOVA) between the Nb wave peak latency (38 ms-48 ms range) of the two groups, viz., congenitally blind and normal sighted [F for Factor A = 5.35, since F.05 (1) 1,36 = 4.1 1, hence p < .05 ]. However, there was no significant difference between the repeat assessments, i.e., RI and R2, Factor B (p > .50), and the interaction between factors (A x B) was also not significant (p > .10). The F value for df = 1.36 has been derived by linear interpolation from the df = 1.30 and df = 1.40 from the standard table as has been described (Zar. 1984). 

Also, the Tukey test for multiple comparisons between mean values showed a marginal significant difference between the mean values (second assessments) of the congenitally blind and normal sighted subjects [q = 3.65, since q at probability level .07 for df = 36, 4 = 3.62, hence p < .07]. The significantly lower Nb wave peak latency in the congenitally blind group was observed as: (1) a difference of more than 3.0 ms in 4 subjects, (2) more than 1.0 ms in 2 subjects, (3) in 3 subjects this difference was less marked (0.56 to 0.83 ms) and (4) in a single CB subject the Nb wave peak latency was higher (by 1.0 ms). Two examples of (1) and a single example of (3) are illustrated in Figure 1. The two factor ANOVA did not show significant differences between either factors or interactions for the peak latencies of the other AEP-MLRs component (p< .20, in all cases).

 [2] Comparison of the peak amplitudes of the Pa and Nb waves recorded from the occipital area (Oz) showed that the peak amplitude of the Pa wave at Oz was significantly lower in the congenitally blind compared to the normal vision group [F for Factor A= 5.07, since F.05 (1) 1,36 = 4.11, hence p <.05]. There was no significant difference between repeat assessments or interaction between factors (Factors B, A x B, p > .20) for Pa wave. For the Nb wave there were also no sig- nificant differences (Factor A, Factor B, A x B, p > .50). 

When recordings were made at Cz, there were no significant differences for all 4 auditory evoked potential components studied (p > .20, for all comparisons).

FIGURE 1:  Three examples of AEP-MLRs recorded in three pairs of congenitally bling(CB) and normal vision(NV) subjects. The first two pairs (I,II) shows examples of noticeabley lower Nb wave peak latency in CB group subjects compared to NV group subjects. The third pair (III) shows a less obvious difference in Nb wave peak latency between the two groups.

The group average values of peak amplitudes and latencies of the four components studied. for the congenitally blind and normal sighted subjects are given in Table 1.

TABLE 1: Peak latencies and peak ainplitudes of AEP-MLRs recorded in congenitally blind (CB) and normal vision (NV) subjects, (N = 1 0)

 
 
Main
  Abstract
  Keywords
  Introduction
Method
  Subjects
  Design of the Study
  Recording of Evoked Potential
  AEP-MLRs Components
  Data Analysis
Results
  Figure
  Table
Discussion
References
You do not have permission to sell or distribute or reproduce Research @ SVYASA Papers text or any portion of the text in any form (printed, electronic or otherwise). To do so is a violation of copyright law

Research Contributions of
SVYASA
(2 Volumes)
PRINT EDITION
US $ 33.00

Write to svyasa@svyasa.org


Apply for
PhD
at
SVYASA
Click here
       
    PDF    
   
     
   
Research Papers Feed
     
   
About US | Contact Us | Feedback | Donate | Press | Careers | Code | Whitepaper